top of page

/Los Angeles, CA

LOS ANGELES, CA · LOS ANGELES COUNTY

As-Built Drawings in Los Angeles, CA

ADS scans buildings with LiDAR and drafts as-built drawings from the scan. In Los Angeles we documented the 3,117 sq ft second floor of a historic institutional building on Olvera Street in May 2026, ahead of a renovation, and delivered Revit, CAD and PDF documentation that keeps its out-of-square walls and uneven floors exactly as they are.

✓

Travel is its own quote line

✓

You own every file

✓

Non-invasive scanning

Scan view of the second-floor corridor of the Sepulveda historic building in Los Angeles, with timber wainscot and a skylight

SEPULVEDA, LEVEL 2 · 3,117 SQ FT · MAY 2026

FROM THE ADS PROJECT FILE

One Los Angeles record, pulled for you

PROJECT RECORD

HISTORIC PRESERVATION

DOCUMENTED 2026

Sepulveda historic building, level 2

As-built documentation and Revit BIM modeling for renovation planning

LOCATION

Olvera Street, downtown Los Angeles, California

BUILDING

Institutional, historic

AREA

3,117 sq ft, second floor

SURVEYED

May 14 to 27, 2026

INSTRUMENT

Leica 3D laser scanner

METHOD

On-site 3D scan and field survey, then scan-to-BIM

Scan view along the second-floor corridor toward the stair at the Sepulveda historic building

Attached: corridor and stair, level 2, as scanned.

PURPOSE

Upcoming renovation: design and planning

CONDITION

Low light, partly dismantled rooms

Historic buildings have structural quirks, so standard measurements were not enough for the renovation ahead. The floor was laser-scanned as it stands and turned into a BIM model the architects could plan from.

FILED UNDER THIS RECORD

Six cards from the Sepulveda file

The delivery was a coordinated Revit, CAD and PDF set, drafted from the point cloud. Each index card below covers one part of the record.

A · PLAN

Dimensioned floor plan of Rooms 6, 7 and 8 on level 2 of the Sepulveda historic building

2D CAD floor plan

Rooms drawn with the dimensions the scan measured, including walls that do not meet at right angles.

B · CEILING

Reflected ceiling plan

Ceilings drawn from the scan, uneven where the building is uneven, and coordinated with the floor plan.

NO PRINT ATTACHED

C · ELEVATIONS

Dimensioned interior elevation of Room 7 showing the existing wall height and openings

Interior elevations

Wall heights, doors, windows and architectural details, room by room.

D · SCHEDULES

Architectural schedules

Schedules coordinated with the plans, ceiling plans and elevations, so the sheets agree with each other.

NO PRINT ATTACHED

E · MODEL

Revit window showing the 3D BIM model of the Sepulveda historic building

Revit model

A BIM model for architectural documentation, design coordination and 3D visualization.

F · POINT CLOUD

Point cloud, plus one extra room

The Leica scan data behind every drawing. An unplanned technical room was scanned as well, and its full LiDAR point cloud was handed over as added value.

NO PRINT ATTACHED

FIELD NOTES

What the crew wrote down on Olvera Street

N1

Low light and dismantled rooms

Limited lighting and partly dismantled areas made capture harder. Scan settings were adjusted room by room.

N2

True geometry, not a tidy version

Non-orthogonal walls, uneven floors and ceilings, facade moldings and existing openings were replicated directly from the point cloud.

Exterior BIM view of the Sepulveda historic building facade with arched openings and a balcony railing

Facade, arched openings and balcony railing

From the BIM model

N3

A dependable base for the renovation

Coordinated Revit, CAD and PDF documentation gives the design team a foundation that reduces risk in the construction phase.

WHAT YOU CAN REQUEST

Fill in a request slip for your own building

Every ADS as-built begins with a LiDAR scan and ends with drawings your architect, engineer or contractor can work from. Mark what you need.

3D laser scanning: a registered point cloud of the whole property, and a 360° digital twin you can open in a browser.

As-built drawings: 2D CAD floor plans, reflected ceiling plans, elevations and sections.

BIM model: Revit at LOD 200 to 300.

MEP documentation: MEP or structural elements when they are in scope.

Building site plans and building surveys, with BOMA or REBNY area calculations on request.

DWG

PDF

RVT

IFC

NWC

E57

Matterport

Handling note. ADS does not have a California office. Crew travel is shown as its own line on the quote, not folded into the drafting price. You review the set and request changes before final delivery.

Request an itemized quote

Send the property address, approximate square footage, the deliverables you need and your deadline. We reply with an itemized quote.

PREFER TO TALK?

CROSS-REFERENCES

Permits and review in Los Angeles

SEE: LADBS

Los Angeles Department of Building and Safety

Plan check, building permits and inspection inside the City of Los Angeles.

Applications are filed through ePlanLA.

Your design professional handles the submittal. Our job is to make sure the existing conditions in it are right. Two entries are worth looking up before you start.

SEE: ORDINANCE 183893

Soft-story retrofit ordinance

Mandatory retrofit of pre-1978 wood-frame soft-story buildings: two or more stories with ground-floor parking or similar open space.

Residential buildings with three or fewer units are exempt.

WHERE WE WORK Downtown and Olvera Street, Hollywood, Koreatown, the Westside, Santa Monica, Beverly Hills, the San Fernando Valley, Pasadena, the South Bay and Long Beach.

REFERENCE DESK

Los Angeles questions, answered on cards

Something else? Call 1-855-201-4043.

Q.01 · HISTORIC

Can you document a historic building without damaging it?

Yes. LiDAR scanning is non-invasive, which is why it suited the Olvera Street building. The point cloud records moldings, openings and deformations exactly, and the model follows the real geometry instead of a cleaned-up version of it.

Q.02 · ACCURACY

Will the walls be drawn straight if they are not?

No. We draw what the scan measured. On the Sepulveda floor that meant non-orthogonal walls, uneven floors and ceilings and facade moldings reproduced as they are, because every dimension comes from the point cloud.

Q.03 · PERMITS

Who issues building permits in the City of Los Angeles?

The Los Angeles Department of Building and Safety (LADBS). It reviews plans, issues building permits and inspects the work, and applications are filed through ePlanLA. Your design professional handles the submittal, and ADS makes sure the existing conditions in it are right.

Q.04 · RETROFIT

Does the soft-story retrofit ordinance apply to my building?

It applies to pre-1978 wood-frame buildings of two or more stories with ground-floor parking or similar open space. That is Ordinance 183893. Residential buildings with three or fewer units are exempt. An accurate existing-conditions set is where the retrofit engineering starts.

Q.05 · SITE VISIT

How long is the site visit for one floor?

One visit. A space the size of the Sepulveda floor, 3,117 sq ft, is captured in a single visit, and offices, stores and homes stay in use while the technician works.

Q.06 · TRAVEL

Is travel included in the drafting price?

No. ADS does not have a California office, so crew travel is shown as its own line on the quote. It is usually small next to the drafting, and you get one crew and one drawing standard across all your sites.

MEMBERSHIPS

ICSC member
Broward County Chamber of Commerce member
Chamber Approved A+
South Florida Women's Chamber of Commerce member

Reviewed by Antonio Tomecich

Founder & Director, As-Built Drawing Services.

Last reviewed November 2026.